The new model control box, which energy-saving mode is provided
The new model control box SC-920C has been newly developed. The control box is resistant to voltage fluctuations, noise and vibration.
The new model control box is provided with an energy-saving mode for the first time in a control box for sewing machines. It reduces power consumption during standby time when the motor is not rotating by approximately 25% (in comparison with the SC-910N).
In addition, the current DDL-8700-7 is lavished with the latest energy-saving technologies, including the adoption of the latest compact servomotor M92, to be more friendly to the environment, as well as to provide the power reducing effect and to increase productivity.
Production support function
Two different operation panels, the CP-18A and CP-180A are applicable to the DDL-8700-7. Both operation panels are provided with the production support function
The production support function actually consists of three different functions (six different modes), which are the output control function, operation measuring function and bobbin counter function.
Output control function
Target No. of products display mode/Target-actual result difference display mode
- Under the target No. of products display mode, the target number of products and the actual number of products produced according to the work hours are displayed.
- In the under target-actual result difference display mode, the difference between the target number of products and the actual number of products produced is displayed
Operation measuring function
Sewing machine availability display mode/Pitch time display mode/Average speed of stitch display mode
- Under the sewing machine availability display mode, the average sewing machine availability in the previous cycle and the current cycle is displayed.
- Under the pitch time display mode, the average process machining time in the previous cycle and the current cycle is displayed.
- Under the average speed of stitch display mode, the accumulated speed of stitch in the previous cycle and the current cycle is displayed.
Bobbin counter function
Bobbin counter display mode
The operator is notified that the bobbin needs to be replaced before the bobbin thread runs out.